AD3000 Professional Conductivity-TDS-TEMP Bench Meter with GLP
AD3000 is a microprocessor-based conductivity, TDS and temperature meter. The autoranging feature of the EC and TDS ranges automatically sets the instrument to the scale with the highest resolution.
Measurements are compensated for temperature effect automatically (ATC) or manually (MTC) with the conductivity probe with built-in temperature sensor. It is also possible to disable the temperature compensation and measure the actual conductivity.
The temperature coefficient is user selectable. The instrument is equipped with a stability indicator, to indicate when measurement is to be recorded.
AD3000 includes also GLP capability. In addition, the meter allows the user to enter an ID code to uniquely identify the instrument.
Calibration Solutions & Accessories
A76309 Conductivity probe with built-in temperature sensor and 1 m cable
A70031P 1413 μS/cm solution, 20 ml sachet, 25pcs
A7031M 1413 μS/cm solution, 230 ml bottle
A70030P 12.88 mS/cm solution, 20 ml sachet, 25pcs
A7030M 12.88 mS/cm solution, 230 ml bottle
A70442P 1500 ppm solution, 20 ml sachet, 25 pcs
A70000P Probe rinsing solution, 20 ml sachet, 25pcs
A7000M Probe rinsing solution, 230 ml bottle
Supplied complete with
AD3000 is supplied complete with A76309 conductivity probe with built-in temperature sensor and 1 m cable, calibration solutions at 1413 μS/cm, and 12.88 mS/cm (20 ml sachet each), 12 Vdc power adapter, electrode holder and user manual.
AD8000 Professional Multi-Parameter pH-ORP-Conductivity-TDS-TEMP Bench Meter
AD8000 is a microprocessor-based pH, ORP, conductivity, TDS and temperature bench meter. Relative mV feature is also provided. The autoranging feature of the Conductivity and TDS ranges
automatically sets the instrument to the scale with the highest resolution.
pH measurements are compensated for temperature effect automatically (ATC) using AD5006 temperature probe, while the EC readings can be compensated automatically (ATC) using the conductivity probe with built-in temperature sensor or manually (MTC). It is also possible to disable the temperature compensation and measure the actual conductivity.
The temperature coefficient is user selectable. The pH calibration can be performed at 1, 2 or 3 points with five memorized buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01). In addition, AD8000 is provided with calibration timeout alarm, GLP feature to view last calibration data and automatic HOLD feature to freeze the first stable reading on the LCD.
Calibration Solutions & Accessories
A1131B Refillable pH electrode with glass body, BNC connector and 1 m cable
A1230B pH electrode with Epoxy body, BNC connector and 1 m cable
A3230B ORP electrode with Epoxy body, BNC connector and 1 m cable
A76309 Conductivity probe with built-in temperature sensor, DIN connector and 1 m cable
A7662 Stainless steel temperature probe with 1 m cable
A70004P pH 4.01 buffer, 20 ml sachet, 25 pcsr
A7004M pH 4.01 buffer, 230 ml bottle
A70007P pH 7.01 buffer, 20 ml sachet, 25 pcs
A7007P pH 7.01 buffer, 230 ml bottle
A70010P pH 10.01 buffer, 20 ml sachet, 25 pcs
A7010M pH 10.01 buffer, 230 ml bottle
A70031P 1413 μS/cm solution, 20 ml sachet, 25pcs
A7031M 1413 μS/cm solution, 230 ml bottle
A7030M 12.88 mS/cm solution, 230 ml bottle
A70442P 1500 ppm solution, 20 ml sachet, 25 pcs
A70000P Probe rinsing solution, 20 ml sachet, 25pcs
A7000M Probe rinsing solution, 230 ml bottle
A70300M Electrode storage solution, 230 ml
A7071S 3.5 M KCl electrolyte solution for refillable electrodes, 30 ml bottle
Supplied complete with
AD8000 is supplied complete with A1131B refillable pH electrode with glass body with BNC connector and 1 m cable, A76309 conductivity probe with built-in temperature sensor and 1 m cable, A7662 stainless steel temperature probe with 1 m cable, pH 4.01 and pH 7.01 calibration buffers (20 ml sachet each), EC calibration solutions at 1413 μS/cm and 12.88 mS/cm (20 ml sachet each), electrode holder,12 Vdc power adapter and user manual.